SDLABIO Biosafety Cabinet Class II
Biosafety Cabinet is a box-type air purification negative pressure safety device that can prevent the loss of aerosols of certain or unknown biological particles during experimental operations. It is widely used in scientific research, teaching, and production in the fields of microbiology, genetic engineering, and biological products. It is a very basic safety protection equipment in the protective barrier of laboratory biology.
MOQ: 1 SET.
biosafety cabinets for sale
| Model (30% Exhaust) | BHC-1000IIA2 (Steel) | BHC-1300IIA2 (Steel) | BHC-1600IIA2 (Steel) |
| Model (100% Exhaust) | BHC-1000IIB2 (Steel) | BHC-1300IIB2 (Steel) | BHC-1600IIB2 (Steel) |
| Cleanliness: | ISO Class 5 @ ≥0.5μm (per U.S. Fed 209E) | ||
| Bacterial Count: | ≤0.5 CFU/dish·hour (φ90mm Petri dish) | ||
| Average Air Velocity: | |||
| Front Interior: | 0.38 ± 0.025 m/s | ||
| Middle: | 0.26 ± 0.025 m/s | ||
| Rear Interior: | 0.27 ± 0.025 m/s | ||
| Inflow Velocity: | |||
| A2 (70% exhaust): | 0.35 + 0.025 m/s | ||
| B2(100% exhaust): | 0.55 + 0.025 m/s | ||
| Air Tightness: | ≤10 m/s (under 500Pa pressure) | ||
| Noise: | ≤62 dB(A) | ||
| Vibration Half Peak Value: | ≤5um | ||
| Illumination: | ≥300LX | ||
| Power supply: | Ac Single Phase 220V/50Hz | ||
| Maximum Power Consumption: | BHC-1000: 0.6KW | BHC-1300: 0.8KW | BHC-1600:1.2KW |
| Weight: | BHC-1000:<200kg | BHC-1300:<250kg | BHC-1600:<300kg |
| HEPA Filter Specifications & Quantity: | BHC-1000: 995×600×38 mm ×1 | BHC-1300: 1295×600×38 mm ×1 | BHC-1600: 1595×600×38 mm ×1 |
| Fluorescent/UV Lamp Specification & Quantity: | BHC-1000: 20W ×1 / 20W ×1 | BHC-1300 & BHC-1600: 30W ×1 / 30W ×1 | |
| Working Area Dimensions: | BHC-1000: 1000×700×680 mm | BHC-1300: 1300×700×680 mm | BHC-1600: 1600×700×680 mm |
| Overall Dimensions: | BHC-1000: 1200×780×1950 mm | BHC-1300: 1500×780×1950 mm | BHC-1600: 1800×780×1950 mm |
biosafety cabinet Feature
Sdlabio ‘s bio safety cabinet use high-quality cold-rolled steel plates. Cold rolling is to further thin the steel plates to the target thickness below the recrystallization temperature at room temperature. The cold-rolled steel plates have a smooth surface, long service life and strong toughness.
Standard 100-level purification
Uses large-area HEPA filter without partition, with strong filtration performance and good effect, and is the most widely used filter material
Bio-safety cabinet with UV light sterilization eliminates any potential microbial contamination
a fume hood vs biosafety cabinet
- 1. Biosafety Cabinet
Biosafety cabinet is an important equipment in the laboratory to prevent experimental items from causing harm to experimental personnel and the environment. It can not only prevent aerosols and droplets generated during experimental operations from spreading to the laboratory, but also prevent experimental personnel from being infected by experimental media. Biosafety cabinets are usually used to operate biological materials, cell culture and virology experiments. - 2. Fume hood
Fume hood is mainly used to handle chemicals, such as preparing solutions, mixing solutions, precipitates, and dissolving solid samples. The essential purpose of the fume hood is to quickly discharge harmful substances through fresh air and exhaust to protect experimental personnel.
- Contact us via Email