SDLABIO Rainin Pipette Tips
SDLABIO Rainin pipette tips are designed and manufactured specifically for Rainin manual and electronic pipettes, ensuring precise fit and high-precision, leak-tight seals. The product range includes universal tips with standard conical interfaces and specialized tips for the Rainin LTS (LiteTouch System), meeting a wide range of experimental needs, including basic research, molecular diagnostics, cytology, and high-throughput analysis.
Rainin Pipette Tips For Sale:
20 μl/200 μl/300 μl/1000 μl/1200 μl; with/without filter; sterile/non-sterile; low retention tips optional.
MOQ: 1 CARTON.
rainin pipette tips for Sale
| Cat No. | Specification | Package |
| RDP-20 | 20 μl;bagged | 500 pcs/pack, 20 packs/ctn |
| RHP-20-S | 20 μl;boxed;sterile | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn |
| RDZ-20 | 20 μl;stacked boxes | 10 stacks/medium box, 10 medium boxes/ctn |
| RDZ-20-S | 20 μl;stacked boxes;sterile | 10 stacks/medium box, 10 medium boxes/ctn |
| RDP-200 | 200 μl;bagged | 1000 pcs/pack, 20 packs/ctn |
| RHP-200-S | 200 μl;boxed;sterile | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn |
| RDZ-200 | 200 μl;stacked boxes | 10 stacks/medium box, 10 medium boxes/ctn |
| RDZ-200-S | 200 μl;stacked boxes;sterile | 10 stacks/medium box, 10 medium boxes/ctn |
| RDP-300 | 300 μl;bagged | 500 pcs/pack, 20 packs/ctn |
| RHP-300-S | 300 μl;boxed;sterile | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn |
| RDZ-300 | 300 μl;stacked boxes | 10 stacks/medium box, 10 medium boxes/ctn |
| RDZ-300-S | 300 μl;stacked boxes;sterile | 10 stacks/medium box, 10 medium boxes/ctn |
| RDP-1000 | 1000 μl;bagged | 500 pcs/pack, 20 packs/ctn |
| RHP-1000-S | 1000 μl;boxed;sterile | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn |
| RDZ-1000 | 1000 μl;stacked boxes | 10 stacks/medium box, 10 medium boxes/ctn |
| RDZ-1000-S | 20 μl;stacked boxes;sterile | 10 stacks/medium box, 10 medium boxes/ctn |
| RHP-1200 | 1200 μl;boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn |
| RHP-1200-S | 1200 μl;boxed;sterile | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn |
| RDL-20 | 20 μl;bagged;with filter | 500 pcs/pack, 20 packs/ctn |
| RHL-20-S | 20 μl;boxed;with filter;sterile | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn |
| RDL-200 | 200 μl;bagged;with filter | 1000 pcs/pack, 20 packs/ctn |
| RHL-200-S | 200 μl;boxed;with filter;sterile | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn |
| RDL-300 | 300 μl;bagged;with filter | 1000 pcs/pack, 20 packs/ctn |
| RHL-300-S | 300 μl;boxed;with filter;sterile | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn |
| RDL-1000 | 1000 μl;bagged;with filter | 1000 pcs/pack, 5 packs/ctn |
| RHL-1000-S | 1000 μl;boxed;with filter;sterile | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn |
| RDL-1200 | 1200 μl;bagged;with filter | 1000 pcs/pack, 5 packs/ctn |
| RHL-1200-S | 1200 μl;boxed;with filter;sterile | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn |
| The above specifications can be equipped with low retention tips. | ||
| ZDLXT-20-R | 20 µL automated filter pipette tips;boxed | 96 pcs/box, 50 boxes/ctn |
| ZDLXT-200-R | 200 µL automated filter pipette tips;boxed | 96 pcs/box, 50 boxes/ctn |
| ZDLXT-1000-R | 1000 µL automated filter pipette tips;boxed | 96 pcs/box, 50 boxes/ctn |
Feature of rainin pipettes tips
- Precise Compatibility with Rainin Pipettes: Tips are designed and manufactured to exacting specifications across all Rainin pipette series, ensuring stable fit and precise pipetting.
- Full Range Coverage: Available in common capacities such as rainin 20ul pipette tips, rainin 200ul pipette tips, rainin pipette tips 300ul, rainin 1000ul pipette tips, and 1200μL, they support a wide range of applications, from microdispensing to large-volume dispensing.
- Choose from a variety of models: Standard models are suitable for pipettes with classic conical interfaces; Rainin LTS pipette tips reduce resistance during tip loading and unloading, making them suitable for long-term, high-throughput operations; filter tip pipette prevent aerosol contamination and are suitable for molecular experiments such as PCR/qPCR/NGS; and low retention pipette tips reduce trace sample residues such as nucleic acids and proteins.
- High-Cleanliness Manufacturing: Produced in a Class 100,000 cleanroom, guaranteed to be free of DNase, RNase, and pyrogen contamination.
- Gamma-ray sterilization options are available. Autoclavable: Made of medical-grade polypropylene (PP), it can be autoclaved at 121°C for 15-20 minutes without deformation.
- Excellent Value: While maintaining performance comparable to genuine Rainin tips, it significantly reduces laboratory consumable costs.
FAQ of rainin pipette tip
Is there a significant performance difference between SDLABIO Rainin tips and genuine tips?
SDLABIO tips are rigorously controlled in terms of size and cleanliness, comparable to genuine Rainin tips. They guarantee pipetting accuracy and sealing performance while offering a better value.
What's the difference between LTS tips and standard tips?
LTS tips feature a cylindrical interface design, offering low insertion and removal resistance and suitable for extended use. However, they are compatible only with Rainin LTS pipettes. Standard tips are compatible with pipettes with a classic conical interface.
What's the difference between sterile and non-sterile pipette tips?
Sterile tips are gamma-irradiated and sterility-tested, making them suitable for applications requiring high cleanliness, such as molecular diagnostics and cell therapy. Non-sterile tips are intended for routine research.
What are my choices of pipette tips?
- Universal pipette tips: Available with or without filters.
- Automation tips: Compatible with workstations from Tecan, Hamilton, Agilent, Rainin, Beckman, Eppendorf, Thermo Fisher, Integra, Perkin Elmer, and Opentrons.
- Gel loading tips.
- Capillary tips.
What are the advantages and features of Rainin LTS tips?
1. Easy Loading and Unloading (LiteTouch System)
- The LTS tip utilizes a non-tapered cylindrical design, requiring less hand force to load and unload than traditional conical tips.
- This significantly reduces hand fatigue during extended pipetting operations, improving experimental efficiency.
2. High Precision and Tightness
- Made using high-precision molds, it ensures a perfect fit with Rainin LTS pipettes.
- It maintains an airtight seal without requiring force, reducing pipetting errors and making it ideal for micro-volume pipetting.
3. Multiple Volumes and Versions
- Common volumes include 10 µL, 20 µL, 200 µL, and rainin pipette tips 1000ul.
- A low retention version is available to reduce sample carryover for proteins, nucleic acids, and other samples.
- Both rainin filter pipette tips and non-filter-type versions are available to meet diverse experimental needs.
4. Strong Compatibility
- Fully compatible with Rainin LTS series manual, electronic, and multichannel pipettes.
- Designed specifically for the LTS interface, ensuring pipetting accuracy and a comfortable feel.
5. Cleaning and Sterilization
- Free from DNase, RNase, and pyrogen contamination, suitable for molecular biology and PCR/qPCR experiments.
- Gamma-irradiation or autoclave sterilization options are available, making them suitable for research and GMP/IVD applications.
6. Improved Experimental Efficiency
- The light-touch design, low-residue materials, and high-precision fit make long-term, high-throughput pipetting easier and more reliable.
- Contact us via Email
- Contact us via Whatsapp