SDLABIO Universal Filter Pipette Tips
SDLABIO Universal filter pipette tips utilize high-quality hydrophobic filters to effectively block aerosol and liquid contamination, ensuring reliability in critical experiments such as molecular biology, clinical testing, and pharmaceutical R&D.
Universal Filter Pipette Tips For Sale:
10 μl/20 μl/50 μl/100 μl/200 μl/1000 μl/1250 μl/5ml/10ml; bagged/boxed.
MOQ: 1 CARTON.
universal filter pipette tips for Sale
| Cat No. | Specification | Package | Weight(kg) | Size(cm) |
| DLXT-10D | 10 μl(32mm);bagged | 1000 pcs/pack, 10 packs/ctn | 1.9 | 39*32*17 |
| DLXT-10 | 10 μl(39mm);bagged | 1000 pcs/pack, 10 packs/ctn | 2.9 | 39*32*18 |
| DLXT-10J | 10 μl extended(45mm); bagged | 1000 pcs/pack, 10 packs/ctn | 2.8 | 39*32*17 |
| DLXT-20 | 20 μl(51mm);bagged | 1000 pcs/pack, 10 packs/ctn | 4.3 | 45*38*25 |
| DLXT-50 | 50 μl(51mm);bagged | 1000 pcs/pack, 10 packs/ctn | 4.3 | 45*38*25 |
| DLXT-100 | 100 μl(51mm);bagged | 1000 pcs/pack, 10 packs/ctn | 4.3 | 45*38*25 |
| DLXT-200 | 200 μl(51mm);bagged | 1000 pcs/pack, 10 packs/ctn | 4.3 | 45*38*25 |
| DLXT-200H | 200 μl(51mm);bagged; yellow | 1000 pcs/pack, 10 packs/ctn | 4.3 | 45*38*25 |
| DLXT-200J58.5 | 200 μl extended(58.5mm); bagged | 1000 pcs/pack, 10 packs/ctn | 4.8 | 47*38*25 |
| DLXT-200J91 | 200 μl extended(91mm); bagged | 1000 pcs/pack, 10 packs/ctn | 10.8 | 69*54*32 |
| DLXT-1000J | 1000 μl(86mm); bagged | 1000 pcs/pack, 10 packs/ctn | 10.5 | 66*54*32 |
| DLXT-1000 | 1000 μl(78mm); bagged; blue | 1000 pcs/pack, 10 packs/ctn | 10.3 | 60*54*32 |
| DLXT-1250 | 1250 μl(101.5mm); bagged | 1000 pcs/pack, 10 packs/ctn | 10.8 | 58*45*50 |
| DLXT-5000D | 5ml; wide mouth; compatible with Eppendorf, DLAB, and Sartorius; bagged | 100 pcs/pack, 10 packs/ctn | 10.8 | 58*45*50 |
| DLXT-5000X | 5ml; small mouth; compatible with Thermo Fisher and BRAND; bagged | 100 pcs/pack, 10 packs/ctn | 10.8 | 58*45*50 |
| DLXT-10000D | 10ml; wide mouth; compatible with Eppendorf, DLAB, and Sartorius; bagged | 100 pcs/pack, 10 packs/ctn | 11.8 | 58*45*50 |
| DLXT-10000X | 10ml; small mouth; compatible with Thermo Fisher and BRAND; bagged | 100 pcs/pack, 10 packs/ctn | 11.8 | 58*45*50 |
| HLXT-10 | 10 μl(32mm);boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 8.5 | 48*29*37 |
| HLXT-10J | 10 μl extended(45mm); boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 8.5 | 48*29*37 |
| HLXT-20 | 20 μl(51mm);boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 9.5 | 48*29*37 |
| HLXT-50 | 50 μl(51mm);boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 9.5 | 48*29*37 |
| HLXT-100 | 100 μl(51mm);boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 9.5 | 48*29*37 |
| HLXT-200 | 100 μl(50.5mm);boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 9.3 | 48*29*37 |
| HLXT-200H | 100 μl(50.5mm);boxed; yellow | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 9.3 | 48*29*37 |
| HLXT-200J58.5 | 200 μl extended(58.5mm); boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 9.6 | 48*29*37 |
| HLXT-200J91 | 200 μl extended(91mm); boxed | 96 pcs/box, 40 boxes/ctn | 15.1 | 58*34*57 |
| HLXT-1000J | 1000 μl(86mm); boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 15.6 | 58*34*57 |
| HLXT-1250 | 1250 μl(101.5mm); boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 15.9 | 56*34*58 |
| HLXT-5000D | 5ml; wide mouth; compatible with Eppendorf, DLAB, and Sartorius; boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 15.9 | 60*48*32 |
| HLXT-5000X | 5ml; small mouth; compatible with Thermo Fisher and BRAND; boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 15.9 | 66*31*39 |
| HLXT-10000D | 10ml; wide mouth; compatible with Eppendorf, DLAB, and Sartorius; boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 16.3 | 66*31*39 |
| HLXT-10000X | 10ml; small mouth; compatible with Thermo Fisher and BRAND; boxed | 96 pcs/box, 10 boxes/medium box, 5 medium boxes/ctn | 16.3 | 66*31*39 |
Feature of universal disposable pipette filter tips
- High-efficiency hydrophobic filter: Effectively blocks aerosols and liquid back-aspiration, reducing the risk of cross-contamination; suitable for high-sensitivity experiments such as PCR, qPCR, and NGS.
- Clean and contaminant-free production: Produced in a Class 100,000 dust-free laboratory; each batch is tested for DNA-free, RNase-free, and pyrogen-free status.
- High-precision mold manufacturing: Uniform pipette wall thickness ensures pipetting accuracy. Low retention pipette tips are available to reduce sample waste.
- Wide compatibility: Compatible with manual and electronic pipettes from Eppendorf, Gilson, Rainin, Thermo, Agilent,etc. Bagged pipette tips/boxed lab pipette tips are optional.
- Multiple volume options: 10ul filter pipette tips, 20 ul pipette tips, 50 ul micro pipette tips, 100 microliter pipette tips, 200ul pipette tips, 1000 ul pipette tips, 1250ul pipette tips, 5ml universal pipette tips, and 10 ml pipette tips with filters. Available in various versions: plain, graduated pipette tips, long, and extended. Sterile pipette tips/non-sterile are also available.
FAQ of filter tip pipette
Filtered vs Unfiltered pipette tips
1. What are unfiltered pipette tips?
- Definition: Standard plastic tips (usually polypropylene) with no internal barrier.
- When to use: Routine liquid handling (buffers, media, nonhazardous reagents).
- When contamination risk is low. Advantages: Less expensive. Widely available in many sizes and formats.
- Limitations: No protection against aerosols or liquid carryover into the pipette body. Risk of contaminating the pipette if accidentally aspirating too far.
2. What are filtered pipette tips?
- Definition: Tips containing a porous barrier (usually hydrophobic polyethylene) inside the upper part of the tip.
- Purpose: Prevent aerosols, vapors, or liquids from reaching the pipette shaft.
- When to use: PCR, qPCR, RT-PCR, sequencing (to avoid nucleic acid contamination). Working with infectious, radioactive, or hazardous samples. Pipetting viscous or volatile liquids (reduces cross-contamination risk).
- Advantages: Protects both sample and pipette. Reduces risk of aerosol-based contamination in sensitive assays.
- Limitations: Higher cost. Some filters are non-autoclavable (check manufacturer). If using a positive displacement pipette, filter tips are unnecessary.
What are my choices of pipette tips?
- Universal pipette tips: Available with or without filters.
- Automation tips: Compatible with workstations from Tecan, Hamilton, Agilent, Beckman, Rainin, Eppendorf, Thermo Fisher, Integra, Perkin Elmer, and Opentrons.
- Gel loading tips.
- Capillary tips.
How to find the right pipette tip?
1. Match the tip to the pipette brand/model
- Check manufacturer recommendations first. Many pipette makers specify compatible tips to ensure accuracy.
- Universal tips vs. proprietary tips: Universal tips fit most air-displacement pipettes (Eppendorf, Gilson, Thermo, etc.), but the fit quality varies. Proprietary tips (e.g., Rainin LTS, Thermo ClipTip) have unique designs and require their own tips.
- Test for fit: When you press the tip onto the pipette, it should seat firmly without rocking or needing excessive force.
2. Choose the right volume range
- Always match the tip to your pipette’s max volume.
- Using an oversized tip (e.g., 1000 µL on a 200 µL pipette) reduces accuracy and can cause leakage.
3. Decide if you need filtered or unfiltered tips
- Filtered tips: Use for PCR, RNA/DNA work, cell culture, or hazardous samples to prevent aerosol contamination.
- Non filtered pipette tips: Fine for routine buffers, media, and non-critical solutions (lower cost).
4. Consider special features
- Low-retention tips: For proteins, viscous liquids, or small volumes to reduce sticking.
- Sterile/Pre-racked: For clinical or aseptic work.
- Conductive pipette tips: Required for some automated liquid handling systems (for liquid-level sensing).
- Extended length pipette tips: Reduce contamination risk when reaching into deep tubes or bottles.
- Contact us via Email
- Contact us via Whatsapp